Su Yalıtım Membranlarında CE Belgesi
The applicable standard is determined by the membrane’s intended use (roofing, basement waterproofing or damp proofing) and material composition (bituminous, plastic or rubber). For applications subject to AVCP System 2+ under these four standards, the manufacturer determines the performance of the product type, implements Factory Production Control (FPC), and prepares the Declaration of Performance (DoP). A Notified Body assesses the FPC system and issues a Certificate of Conformity of Factory Production Control. Characteristics such as external fire performance and reaction to fire may be subject to different assessment systems.
| Application | Bituminous Membranes | Plastic and Rubber Membranes |
|---|---|---|
| Roofing | EN 13707 – Reinforced bitumen sheets for roof waterproofing | EN 13956 – Plastic and rubber sheets for roof waterproofing (PVC, TPO, EPDM, etc.) |
| Basement waterproofing and damp proofing | EN 13969 – Bitumen damp proof sheets, including basement tanking | EN 13967 – Plastic and rubber damp proof sheets, including basement tanking |
EN 13707 covers reinforced bituminous roofing membranes manufactured using APP- or SBS-modified bitumen and reinforced with materials such as polyester fleece or glass fibre. The standard includes underlays and cap sheets used in multi-layer roofing systems, including mineral-surfaced and foil-faced products.
EN 13956 covers synthetic membranes manufactured from materials such as PVC-P, TPO/FPO and EPDM, primarily used in single-ply roofing systems. These membranes may be installed in mechanically fastened, adhered or ballasted roofing systems.
EN 13967 and EN 13969 cover waterproofing and damp-proofing sheets used to protect structures against moisture and water from the ground, including foundations, retaining walls and floor slabs. Basement waterproofing (tanking) applications also fall within the scope of these standards.
Where a product is intended to be marketed for both roofing and basement waterproofing applications, the relevant requirements of both standards must be fulfilled separately, and each intended use must be clearly identified in the Declaration of Performance (DoP). In such cases, the FPC plan must also include controls supporting both declared applications.
The characteristics to be declared depend on the applicable standard and the product’s intended use. Commonly assessed characteristics include:
| Essential Characteristic | Description |
|---|---|
| Watertightness | Testing for watertightness under a specified pressure |
| Tensile properties | Tensile strength and elongation at break in longitudinal and transverse directions |
| Tear resistance | Resistance to tearing by a nail shank |
| Impact resistance | Ability to maintain watertightness under impact loading |
| Resistance to static loading | Particularly relevant to accessible or ballasted roofing systems |
| Flexibility at low temperature | Cold-bending temperature for bituminous membranes |
| Joint strength | Peel and shear resistance of overlaps and welded joints |
| Root resistance | Relevant to products intended for green roof applications |
| Dimensional stability | Dimensional changes following thermal exposure |
| Durability | Retention of properties following artificial ageing (UV exposure and heat) |
| External fire performance | Roofing classifications such as B_ROOF(t1) to B_ROOF(t4) |
| Reaction to fire | Euroclass classification (A1 to F) |
For basement waterproofing and damp-proofing membranes, characteristics such as water vapour permeability, chemical resistance and resistance to the alkalinity of concrete are also particularly relevant.
Manufacturer:
Notified Body:
Under System 2+, the Notified Body does not perform product-type testing. The document commonly referred to as a “CE certificate” in the construction products sector is the Certificate of Conformity of Factory Production Control, issued following the assessment process.
For waterproofing membranes, the applicable AVCP system may vary depending on the characteristic being assessed and the intended use. For example, external fire performance and reaction to fire may be subject to different assessment systems. These characteristics may therefore require the involvement of an additional testing laboratory or another Notified Body. The applicable assessment systems are specified in Annex ZA of the relevant standard. Sertifike’s Notified Body designation is limited to System 2+.
Manufacturers applying for Factory Production Control (FPC) certification are expected to have the following information and records available before the initial inspection:
CE · 3228
Example Waterproofing Industries Ltd., [address]
26
DoP No.: EX-WM-001
EN 13707:2004+A2:2009
Reinforced bitumen sheet for roof waterproofing, cap sheet in a multi-layer system
Watertightness: Pass · Tensile strength (longitudinal/transverse): [declared value] N/50 mm · Elongation at break: [declared value] % · Nail shank tear resistance: [declared value] N · Flexibility at low temperature: [declared value] °C · External fire performance: [class] · Reaction to fire: [class]
For illustrative purposes only.
The CE certification process begins by identifying the applicable standard-EN 13707, EN 13956, EN 13967 or EN 13969-based on the product’s intended use. The manufacturer performs or commissions the required performance tests and establishes a Factory Production Control (FPC) system covering raw material inspections, manufacturing processes and quality control records. Under AVCP System 2+, the manufacturer applies to a Notified Body, which assesses the manufacturing facility and its FPC system. Following a successful conformity assessment, a Certificate of Conformity of Factory Production Control is issued. The manufacturer then completes any other required assessments, prepares the Declaration of Performance (DoP) and affixes the CE marking to the product.
Are Bituminous Roofing Membranes and Bituminous Basement Waterproofing Membranes Covered by the Same Standard?No. Reinforced bituminous roofing membranes are covered by EN 13707, whereas bituminous damp-proofing sheets, including those used for basement tanking, are covered by EN 13969. These standards establish different performance requirements depending on the intended application. For example, resistance to external weather conditions and external fire performance are particularly important for roofing membranes, while watertightness and resistance to ground-related conditions are essential for basement waterproofing. If the same membrane is marketed for both roofing and basement applications, the relevant requirements of both standards must be fulfilled, and the intended uses must be specified in the Declaration of Performance (DoP).
Which Standards Apply to PVC and TPO Membranes?Plastic and rubber membranes, including PVC-P, TPO/FPO and EPDM, used for roof waterproofing are covered by EN 13956. Plastic and rubber sheets intended for basement waterproofing, foundation protection and damp proofing fall within the scope of EN 13967. The applicable standard is determined not only by the membrane’s material composition but also by its intended use. Therefore, manufacturers should clearly identify the applications for which their products will be marketed before initiating the CE certification process.
What Does B_ROOF(t1) Mean?B_ROOF(t1) is a classification describing the performance of roof systems when exposed to external fire. The designation B_ROOF indicates the performance classification, while t1 identifies the test method used. External fire performance assessments may involve four different test methods, designated t1, t2, t3 and t4. The required classification and test method depend on the regulations of the country where the product will be used and the characteristics of the roof system. This classification is distinct from the material’s reaction-to-fire classification.
Does the Notified Body Conduct External Fire Performance Tests?Sertifike’s role in the waterproofing membrane sector is to provide Factory Production Control (FPC) certification under AVCP System 2+. External fire performance and reaction-to-fire characteristics are assessed separately according to the conformity assessment systems specified in Annex ZA of the relevant standard. Where required, an appropriately designated testing laboratory or another Notified Body may be involved in verifying these characteristics. Therefore, an FPC Certificate of Conformity does not indicate that all fire performance tests have been conducted by the Notified Body responsible for FPC certification.
What Additional Performance Characteristic Must Be Declared for Green Roof Applications?For waterproofing membranes used in vegetated roofing systems, resistance to root penetration is an important performance characteristic. Root resistance is evaluated using the relevant test methods to prevent plant roots from damaging the membrane and compromising the integrity of the waterproofing system. Where required by the applicable standard and intended use, membranes marketed for green roof applications are expected to include this characteristic in their Declaration of Performance (DoP). Other relevant watertightness and mechanical resistance requirements must also be satisfied.
Must Membrane Thickness Be Declared in the Declaration of Performance (DoP)?Membrane thickness and mass per unit area are important characteristics for product identification and Factory Production Control. During manufacturing, thickness, width, mass per unit area and dimensional characteristics are monitored against specified tolerances. However, the characteristics that must be included in the Declaration of Performance (DoP) are determined by the relevant provisions of the applicable product standard. Information provided on product labels, technical data sheets and the DoP must remain consistent. Significant changes in thickness or raw material composition may require reassessment of the product’s performance.
Is CE Certification Mandatory for Waterproofing Membranes?CE marking is mandatory for waterproofing membranes placed on the market within the scope of the relevant harmonised standards. The applicable standard for bituminous, plastic and rubber membranes depends on whether the product is intended for roofing or basement waterproofing applications. For products subject to AVCP System 2+, the manufacturer’s Factory Production Control system must be certified by a Notified Body. However, characteristics such as external fire performance and reaction to fire may be subject to different assessment systems. The manufacturer affixes the CE marking once the required assessments have been completed and the Declaration of Performance has been prepared.
How Much Does CE Certification for Waterproofing Membranes Cost?The cost of CE certification for waterproofing membranes varies depending on the characteristics of the manufacturing facility, the membrane types to be certified, the applicable standards and the scope of assessment activities. Differences in the manufacturing processes for bituminous and synthetic membranes, the inclusion of multiple product families within the certification scope, and the need for additional performance testing may affect the overall cost. Initial certification and continuing surveillance activities must also be taken into account. For a certification scope and up-to-date quotation tailored to your products and manufacturing facility, you can request a quotation from Sertifike.
Concrete Admixtures CE Certification: EN 934 Standards Guide Chemical admixtures, including water reducers, superplasticizers, set…
EN 998-2 Masonry Mortar CE Certification: System 2+ Guide Factory-produced masonry mortars are placed on…
Geotextile CE Certification: EN 13249 & Geosynthetic Standards Geotextiles, geomembranes, geogrids, geocomposites and geonets used…
Products used for the repair and protection of damaged concrete in bridges, tunnels, parking structures,…
How to Prepare a CE Declaration of Conformity? One of the most important stages of…
How to Prepare a CE Technical File? (Step-by-Step Guide) One of the most critical stages…